BXRCD - OMC PREMIUM BLEND GEARCASE LUBRICANT, 60-376, 172819
- MSDS: BXRCD
- Manufacturer: CITGO PETROLEUM CORP
- Product Name: OMC PREMIUM BLEND GEARCASE LUBRICANT, 60-376, 172819
- National Stock Number: 9150-01-107-2719
Product Identification
Product ID:OMC PREMIUM BLEND GEARCASE LUBRICANT, 60-376, 172819
MSDS Date:09/26/1985
FSC:9150
NIIN:01-107-2719
MSDS Number: BXRCD
Responsible Party
US
Emergency Phone: 318-491-6215
Info Phone: 918-561-5165
Cage: 1JW40
Contractor
Telephone: 918-561-5165
Cage: 12518
Ingredients
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED LIGHT
CAS: 64742-56-9
RTECS: PY8039500
Fraction By Weight: 83-95%
OSHA PEL 300 PPM
ACGIH TLV: 300 PPM
HYDROTREATMENT; (REFINED PETROLEUM OIL) LD50
RTECS: 9999999ZZ
MINERAL OIL, PETROLEUM DISTILLATE, SOLV-DEWAXED HEAVY
CAS: 64742-65-0
RTECS: PY8038501
Fraction By Weight: 83-95%
OSHA PEL N/K
ACGIH TLV: N/K
SOLVENT DEWAXED RESIDUAL OIL (PETROLEUM); (REFINED
CAS: 64742-62-7
Fraction By Weight: 83-95%
OSHA PEL N/K
ACGIH TLV: N/K
ANTI-OXIDANT
Fraction By Weight: <3%
OSHA PEL N/K
ACGIH TLV: N/K
VI IMPROVER (TYPE NOT SPECIFIED)
Fraction By Weight: <5%
OSHA PEL N/K
ACGIH TLV: N/K
56).
RTECS: 9999999ZZ
AS OIL MIST. (ACGIH 1984-85; OSHA 1972).
RTECS: 9999999ZZ
FREQUENT OR PROLONGED CONTACT IS EXPECTED.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TOX:SLIGHTLY TOXIC, 1 PT-1 QT IS
APPROX LETHAL ORAL DOSE FOR 150 LB HUMAN ADULT. ACUTE:INHAL:LOW
RISK. IN ENCLSD SPACES/WHEN HOT, VAPS MAY REACH CONCS SUFFICIENT TO
CAUSE DROW, DIZZ, HDCH, NAUS/LUNG I RRIT. MISTS ABOVE TLV MAY CAUSE
CHEM PNEUM. SKIN:LOW IRRIT. SKIN ABSORP:NO PROBABLE HAZ. EYE:MAY BE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:MILDLY IRRIT. INGEST:GEN LOW TOX.
VERY LG AMTS MAY CAUSE GENERALIZED DEPRESS, HDCH, DROW, NAUS,
VOMIT/DIARR. SM DOSES MAY PRDCE IRRIT & DIARR. CHRONIC:PRLNGD &/OR
FREQUENT CONT MAY CAUSE DRY ING, CRACKING (DERMATITIS) OR
FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. RESP SUPPORT IF NEC. SEEK MED AID.
SKIN:WASH W/SOAP & WATER. DO NOT WEAR HEAVILY CONTAM CLTHG BEFORE
LAUNDERING. EYES:FLUSH W/LG VOLS OF WATER FOR @ LST 15 MINS. SEE MD
IF A NY COMPLICATIONS ARISE. INGEST:DO NOT INDUCE VOMIT. SEEK MED
AID. INJECTION:SUBCUTANEOUS INJECTION IS MED EMER. SEEK MED AID
IMMED. NOTE TO MD:IF VISCOSITY IS <100 SUS @ 100F CAREFUL GASTRIC
(SUPDAT)
Fire Fighting
Flash Point Method:COC
Flash Point:379F,193C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM OR WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.
Accidental Release
Spill Release Procedures:REMOVE SOURCES OF HEAT OR IGNITION, PROVIDE
ADEQUATE VENTILATION, CONTAIN LEAK. ABSORB SMALL SPILLS WITH
SUITABLE MATERIAL SUCH AS RAGS, STRAW OR SAND. REPORT SPILLS AS
REQUIRED TO APPROPRIATE AUTHORI TIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE BELOW 120F. DOT HAZARD LABEL NOT
REQUIRED. DO NOT APPLY HIGH HEAT OR FLAME TO CONTAINER. KEEP
SEPARATE FROM STRONG OXIDIZING AGENTS.
Other Precautions:EMPTY CNTNRS MAY CNTN PROD RESIDUE WHICH COULD
INCLUDE FLAM/EXPLOS VAPS. CONSULT APPROP FED, STATE & LOC AUTHS
BEFORE REUSING, RECONDITIONING, RECLAIMING, RECYCLING/DISPOSING OF
EMPTY CNTNRS &/OR WAST E RESIDUES OF THIS PRODUCT.
Exposure Controls
Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED-USE NIOSH/MSHA APPROVED RESPIRATOR FOR
ORGANIC VAPORS AND MISTS.
Ventilation:VENT IS REQ WHEN WORK PLACE EXPOS EXCEED TLV. VERY HIGH
MIST CONCS CAN RSLT IN FIRE & EXPLO HAZ. TLV:5 MG/CU M (ING 8)
Protective Gloves:OIL IMPERVIOUS GLOVES IF (ING 9)
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE.
Work Hygienic Practices:LAUNDER SOILED WORK CLOTHES BEFORE REUSE.
Supplemental Safety and Health
FIRST AID PROC:LAVAGE W/TIGHT FITTING/CUFFED TUBE IS TO BE PREF OVER
EMESIS. IF VISCOSITY IS >100 SUS @ 100F., EMESIS MAY BE INDUCED FOR
LG QTYS. ASPIR MAY CAUSE CHEM PNEUM/LIPOID PNEUM. SUBCUTANEOUS
INJECTION REQS PROMPT SURGICAL DEBRIDEMENT. IF NOT FAMILIAR
W/TECHNIQUE, SEEK SKILLED ADVICE. SUS VISCOSITY @ (ING 7)
Chemical Properties
Vapor Density:>1
Spec Gravity:0.88 (H*2O=1)
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, MILD ODOR.
Percent Volatiles by Volume:NEG
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:(THERMAL, UNLESS OTHERWISE
SPECIFIED):CO, CO*2.
Disposal
Waste Disposal Methods:IT IS THE RESPONSIBILITY OF THE USER TO
DETERMINE IF THE MATERIAL IS A HAZARDOUS WASTE AT THE TIME OF
DISPOSAL. CHECK BEFORE DISPOSING TO BE SURE YOU ARE IN COMPLIANCE
WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS
.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.